Manufacturers & Solutions
Mission Critical Focus
Built for Speed and Scale
Engineering Partner, Not Just a Vendor

Proven Equipment. Engineered for Mission-Critical Loads.

We represent a select set of manufacturers chosen for one reason: they perform in data centers. Mission Critical focus means deeper product knowledge, stronger factory relationships, and better access to production capacity when your schedule depends on it. We provide the right equipment on a project to project basis.

Manufacturers

Air-Cooled Magnetic-Bearing (MagLev) Chillers for Data Centers
Provide the Make-Up Air The Equipment Needs – Stop Recirculation – Gain Back Capacity and Efficiency

Solutions

Adiabatic Fluid Coolers and Dry Coolers

Closed-Loop Heat Rejection That Saves Water and Energy

Fan Coil Walls

High-Density Air Cooling at Hyperscale
Fan coil walls place large arrays of EC fans behind chilled-water coils along the data hall perimeter, moving massive airflow across the white space with no equipment on the raised floor or in the aisles. They’re designed for elevated water temperatures and tight approach temperatures, which keeps chillers in their most efficient range and maximizes free-cooling hours. Modular sections scale with the hall and allow maintenance without taking cooling offline.

CRAH and CRAC Units

Precision Cooling for Every Room in the Facility
Computer room air handlers (CRAH, chilled water) and computer room air conditioners (CRAC, direct expansion) provide precise temperature and humidity control for data halls, network rooms, electrical rooms, and UPS and battery spaces. Our perimeter and in-room units are built for 24/7 operation, with EC fans, variable-capacity compressors, and intelligent controls that coordinate units as a team instead of letting them fight each other.

Thermal Energy Storage Tanks

Cooling Ride-Through and Load Shifting
When utility power drops, IT load keeps generating heat while chillers restart behind the generators. Chilled-water thermal energy storage (TES) tanks bridge that gap, carrying the data center through chiller restart and power transfer without a temperature excursion. The same tanks can shift chiller load to off-peak hours, reduce demand charges, and let you size the plant closer to average load.

Pump and Prefab Pipe Skids

Factory-Built Hydronics That Shorten the Schedule
On-site pipe fitting is one of the biggest schedule risks on a data center build. Our prefabricated pump and pipe skids move that work into a controlled factory: pumps, VFDs, valves, strainers, instrumentation, controls, and interconnecting piping, assembled on a structural frame and tested before shipment. Skids arrive ready to set, connect, and commission, with fewer trades on site and more predictable quality.

Acoustical Treatment

Meeting Noise Ordinances Without Sacrificing Capacity
Large chiller and cooler yards run around the clock, and data centers increasingly sit near homes with strict day and night noise limits. Noise has become a permitting and community-acceptance risk, not an afterthought. We provide engineered acoustical solutions for chiller yards, rooftops, and generator areas, designed together with the cooling equipment so attenuation never restricts airflow or causes hot-air recirculation.

Coolant Distribution Units (CDUs)

AI and high-performance computing racks now produce more heat than air alone can remove. Coolant distribution units connect the facility chilled-water loop to the technology cooling loop that feeds cold plates on the servers. A CDU keeps the IT loop separate through a heat exchanger and holds supply temperature, pressure and flow within tight limits. It also filters the coolant and keeps it clean, protecting the expensive hardware on the other side.

How we help you buy

01
Basis-of-design support
Selections, performance data, and spec language for MEP engineers
02
Spec and submittal review
Deviations flagged early, not after award
03
Commercial structuring
ROM pricing, lead times, MSA terms
04
Production and logistics
Factory slot management, shipping coordination, staged deliveries
05
Startup and support
Factory startup, commissioning, training, warranty administration
06
Post Sale Support
work with owner direct employees and local service to help service the equipment for its full life cycle

Multistack

Air-Cooled Magnetic-Bearing (MagLev) Chillers for Data Centers
Multistack’s air-cooled MagLev chillers use oil-free, magnetic-bearing centrifugal compressors that deliver high part-load efficiency with fewer wear components. For data centers, that means lower PUE, less maintenance, and no oil management risk across years of 24/7 operation.

ExhaustFlow Technologies (EFT)

Provide the Make-Up Air The Equipment Needs – Stop Recirculation – Gain Back Capacity and Efficiency
On dense rooftop and yard chiller/dry cooler arrays, hot discharge air re-entering condenser coils raises entering-air temperature, cuts capacity, and pushes units toward high-pressure trips on the hottest days. EFT’s patented exhaust technology directs condenser discharge air away from the array to reduce recirculation.